AULT / SL POWER Industrial Partner

FLU1-40-2AD - AULT / SL POWER FLU1-40-2AD OPEN-FRAME SWITCHING POWER SUPPLIES...

larger image

Request Quote
For Price
Part Number:
FLU1-40-2AD
Model Number:
FLU1-40-2AD
Make:
AULT / SL POWER
Lead Time:
Available
Qty In Stock:
Available

AULT / SL POWER FLU1-40-2AD OPEN-FRAME SWITCHING POWER SUPPLIES Simple Type: Power Supply

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 0% Minimum Load Requirement
  • 2-Year Warranty
  • Austel CCL Certification
  • BABT Approvals
  • CEMark: UL/CSA/EN60950 Approvals
  • EN55022/FCC Class B Input Line Filter
  • Medical Safety Approvals
  • Minimum 200,000-Hour MTBF
  • Models with UL544/CSA C22.2-601/EN60-601
  • Over-Current/Short-Circuit Protection
  • Single, Dual and Triple Output Models
  • Universal AC-Input and DC-Input Models

Specifications

    General
  • Altitude: 0 to 10,000 feet.
  • Continuous Output Power: 40W, maximum.
  • Cooling: Convection cooling is adequate.Moving air is recommended for operation in a confined area.
  • DC Output: See table. (Note 2.)
  • Design Topology: Flyback converter with current-mode control.
  • Efficiency: 62-75%, typical (nominal input line voltage, nominal load conditions).
  • EMI Filter: Standard. Performance surpasses conducted EMI requirements of EN55022/FCC Class B by 10 dB, typ.
  • Frequency of Operation: 40 kHz (fixed).
  • Hi-Pot Isolation: FLU Series: 5300 VDC, input-to-out-put for one minute. (Note 3.)
  • Hold-Up Time: FLU and MDU models: 16 ms (115VAC input), 32 ms (230 VAC input),minimum, at full load
  • Input Line Frequency: 47-440 Hz (ac input models).
  • Input Line Protection: MOV transient protected (FLU and MDU series). Input line fuse provided on-board. (See Note 1.)
  • Input Voltage: FLU and MDU models, universal input range 85-265 VAC single phase or 100-370 VDC. DC-input models, 36-75 VDC (48V, nominal).
  • Leakage Current: MDU Series, non-patient contact rating: 500 µA, maximum.
  • Mean Time Between Failures: >200,000 hours. (Note 6.)
  • Noise, Ripple and Spike: 1% peak-to-peak, maximum. (See Note 5.)
  • Output Power De-Rating: De-rate output power and current linearly 2%/°C from +50°C to +70°C.
  • Output Voltage Adjust: Primary output adjustable ±5%.Auxiliary outputs fixed.
  • Over-Voltage Protection: Primary output only.
  • Overload Protection: Power-limit circuit.
  • Relative Humidity: 0 to 95%, non-condensing.
  • Short-Circuit Protection: Continuous.
  • Soft Start: Standard on all models.
  • Storage Humidity: 0 to 95%, non-condensing.
  • Storage Temperature: -40°C to +85°C.
  • Temperature Coefficient: ±0.05%/°C over the entire operating temperature range.
  • Temperature Range: -20°C to +70°C.

 

Applications

  • None Available

Aliases