AULT / SL POWER Industrial Partner

FDA1-150-7BD - Ault/SL Power FDA1-150-7BD Power Supply - 150W AC/DC Switch-Mode Power...

Request Quote
For Price
Part Number:
FDA1-150-7BD
Model Number:
FDA1-150-7BD
Make:
AULT / SL POWER
Lead Time:
Available
Qty In Stock:
Available

Ault/SL Power FDA1-150-7BD Power Supply - 150W AC/DC Switch-Mode Power Supply Simple Type: Power Supply

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 0% Minimum Load Requirement
  • 1.38-Inch Overall Height
  • 150W Continuous Output Power
  • 90-265 VAC Auto-Ranging Input
  • EN55022/FCC Class B Input Line Filter
  • Minimum 165,000-Hour MTBF
  • Optional Power-Fail Warning
  • Over-Voltage/Over-Current/Short-Circuit Protection
  • Remote Load Sensing
  • Single and Dual Output Models
  • UL1950/CSAC22.2-950/EN60950 Standards

Specifications

    General
  • Altitude: 0 to 10,000 feet
  • Continuous Output Power: 150W, maximum
  • Cooling: Convection cooling is adequate. Moving air is recommended for operation in a confined area
  • Design Topology: Forward converter with current-mode control
  • Efficiency: 70%, typical (115 or 230 VAC input)
  • Electrical Strength/Isolation: 5300 VDC, input-to-output for one minute
  • EMI Filter: Standard. Performance surpasses conducted EMI requirements of EN55022/FCC Class B by 10 dB, typ
  • Frequency of Operation: 65 kHz (fixed)
  • Hold-Up Time: 16 ms at 115 VAC input, 32 ms at 230 VAC input, minimum at full load
  • Humidity: Operating:0 to 95%, non-condensing; Storage:0 to 95%, non-condensing
  • Input Current: 3.5A, maximum
  • Input Line Frequency: 47-440 Hz (50/60 Hz, nominal)
  • Input Line Protection: MOV transient protected. Input line fuse provided on-board
  • Input Voltage: Auto-ranging input, 90-265 VAC, single phase
  • Mean Time Between Failures: >165,000 hours
  • Noise, Ripple and Spike: 2% peak-to-peak, maximum
  • Output Power De-Rating: De-rate output power & current linearly 2%/°C from +50°C to +70°C
  • Output Voltage Adjust: Primary output adjustable ±5%. Auxiliary outputs fixed
  • Over-Voltage Protection: Primary output only (120% of rated output voltage, typical)
  • Overload Protection: Power-limit circuit
  • Power-Fail Warning: Optional: TTL-compatible (logic 0, 4 ms, minimum, before loss of output)
  • Short-Circuit Protection: Continuous
  • Soft Start: Standard on all models. Prevents output overshoot and power transformer saturation at start-up
  • Temperature: Operating:-20°C to +70°C; Storage:-40°C to +85°C
  • Temperature Coefficient: ±0.05%/°C over the entire operating temperature range
  • Transient Response: 4 ms recovery to within 1% of the regulation band with no more than 5% deviation

 

Applications

  • None Available

Aliases